The 7F.06 gas turbine provides higher output and efficiency than any other 60 Hz  F-class gas turbine. With the 7F.06, you get both flexibility and performance in a turbine that’s designed to match the quality and standards that you’ve come to expect from GE’s other F-class heavy-duty gas turbines.

LOWEST COST OF ELECTRICITY IN ITS CLASS

The 7F.06 provides the highest MW rating and efficiency across the entire ambient range for F-Class turbines.

PERFORMANCE AND EMISSIONS

The 7F.06 provides the most full-load MW, the fastest ramp rates, the most MW in 10 minutes, the lowest turndown, and the highest F-Class efficiency – all while operating at 9ppm NOx and CO emissions.

GREATER FLEXIBILITY

The 7F.06 turbine provides greater capacity for flexibility, including renewable energy support, and its fast ramp capability of 50 MW per minute further expands its flexibility.
7ha-detail
LM6000-PF+-9_mobile

7F.06 Gas Turbine

Power plant configurations may differ, but one of their goals remains the same – to attain the lowest life cycle cost in the right size for your project. The 7F.06 is GE’s most powerful and efficient 60 Hz F-class gas turbine and benefits from over 40 million hours of GE 7F experience and 2,000 hours of full-speed, full-load validation testing.

  • F-class operating and emission levels deliver extended operation between planned maintenance events at 32,000 hour and 1,250 start intervals
  • Built on the 7F.05 compressor, GE’s industry-leading DLN2.6+ combustion system, and H-class derived four stage hot gas path
  • Significant flexibility enables specific power and exhaust condition customization for each project
  • An optional air-cooled generator provides simplified installation and maintainability
  • Modular systems afford faster and easier installation with 10,000 fewer man-hours than traditional gas turbine applications
  • Faster, more efficient maintenance through a quick-removal turbine roof, field-replaceable blades, and 100 percent borescope inspection coverage for all blades
  • Simplified dual-fuel system uses less water, eliminates recirculation, and uses enhanced liquid purge to enhance dependability and reliability
Want to Learn More? 

Tools & Resources

Explore our range of tools that let you choose products, keep them up and running, and enhance their power potential.

icon-links-final

Product Specifications

7F.06  
SC Net Output (MW) 271
SC Net Heat Rate (Btu/kWh, LHV) 8,179
SC NetHeat Rate (kJ/kWh, LHV) 8,629
SC Net Efficiency (%, LHV) 41.7%
Comp. Pressure Ratio (X:1) 22.1
ExhaustTemperature (°F) 1,094
ExhaustTemperature (°C) 590
Exhaust Energy (MM Btu/hr) 1,287
Exhaust Energy (MM kJ/hr) 1,358
GT Turn-down - Minimum load  (%)  30%
GT Ramp Rate - (MW/minute) 55
NOx (ppmvd) at baseload (@15% O2) 9
CO (ppm) at min. turn-down w/o abatement 9
Wobbe Variation (%)  +/- 7.5%
Startup Time - Conventional / Peaking (min.) 21 / 10
7F.06  
CC Net Output (MW) 396
CC Net Heat Rate (Btu/kWh, LHV) 5,574
CC Net Heat Rate (kJ/kWh, LHV) 5,881
CC Net Efficiency (%, LHV) 61.2%
Plant Turn-down - Minimum load  (%)  36%
Ramp Rate - (MW/minute) 55
Startup Time (RR Hot, minutes) < 30
Bottoming Cycle Type  3PRH 
HP Throttle Press. (psia/bar) 2105/145
HP Throttle Temp. (°F/°C) 1,070/577
Reheat Temp. (°F/°C) 1,060/571
ST Configuration (Type) STF-D650
GT Generator Type (Cooling) Hydrogen
ST Generator Type (Cooling) Air
7F.06  
CC Net Output (MW) 797
CC Net Heat Rate (Btu/kWh, LHV) 5,548
CC Net Heat Rate (kJ/kWh, LHV) 5,854
CC Net Efficiency (%, LHV) 61.5%
Plant Turndown - Minimum load  (%)  17%
Ramp Rate - (MW/minute) 110
Startup Time (RR Hot, minutes) < 30
Bottoming Cycle Type  3PRH 
HP Throttle Press. (psia/bar) 2400/165
HP Throttle Temp. (°F/°C) 1,070/577
Reheat Temp. (°F/°C) 1,060/571
ST Configuration (Type) STF-D650
GT Generator Type (Cooling) Hydrogen
ST Generator Type (Cooling) Hydrogen