Dry Low NOx 2.6+ Combustion Solution

Extend your outage intervals and flexibility with GE’s Dry Low NOx (DLN) 2.6+ combustion system. Building on a rich heritage of combustion leadership, the DLN 2.6+ delivers industry-leading low emissions. Introduced in 2005 on 9F gas turbines, the DLN 2.6+ is now available for 7F units.

Want to Learn More? 
dln-26-circle

What Can DLN 2.6+ Do for You?

  • Reduce NOx emissions to as low as 5 ppm across large load and ambient temperature range of 0°F–120°F
  • Increase availability and lower maintenance costs due to 32,000 factored fired hour (FFH) and 1,250 factored fired start (FFS) combustion intervals
  • Broaden fuel flexibility for gas fuels with up to 30 percent Modified Wobbe Index (MWI), 25 percent ethane/propane, 20 percent hydrogen and a wide range of distillate fuels
  • Extend turndown to as low as 37 percent of baseload for off-peak fuel savings and fast dispatch
  • Enhance Advanced Gas Path (AGP) and compressor upgrade performance and operability
  • Improve flexibility when combined with OpFlex controls software including AutoTune, Fast Start, Cold-Day Performance, and Extended Turndown
  • Eliminate costly diluent injection or Selective Catalytic Reduction (SCR) systems, and the drawbacks associated with ammonia utilization
Technical Data
Fuel NOx† CO†
Natural Gas as low as < 5 ppm ~0–9 ppm
Distillate Oil < 42 ppm 20 ppm

†15% O2 with gas fuel, water injection for liquid fuel